Zircon triscanner pro sl инструкция на русском

TriScanner

Stud & Metal Locator with AC Warning

The Zircon TriScanner

®

Pro SL

scanner detects wood or metal

studs, metal pipes, and hot

Metal Sensor

electrical wires in interior walls,

floors, and ceilings, as well as

AC LED

rebar in concrete. It features

the SpotLite

®

Pointing System,

Stud Scan

three different scanning modes

Mode LED

plus continuous hot electrical

wire detection.

Stud DeepScan

Mode LED

Metal Scan

Mode LED

On/Off Button

(Side of unit)

LIMITED 1 YEAR WARRANTY

Zircon Corporation, («Zircon») warrants this product to be free from defects

in materials and workmanship for one year from the date of purchase. Any

in-warranty defective product returned to Zircon*, freight prepaid with proof

of purchase date and $5.00 to cover postage and handling, will be repaired or

replaced at Zircon’s option. This warranty is limited to the electronic circuitry

and original case of the product and specifically excludes damage caused by

abuse, unreasonable use or neglect. This warranty is in lieu of all other

warranties, express or implied, and no other representations or claims of any

nature shall bind or obligate Zircon. Any implied warranties applicable to this

product are limited to the one year period following its purchase.

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR

CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR

MALFUNCTION OF THIS PRODUCT.

In accordance with government regulations, you are advised that:

(i) some states do not allow limitations on how long an implied warranty lasts

and/or the exclusion or limitation of incidental or consequential damages, so

the above limitations and/or exclusions may not apply to you, and further (ii)

SCANNING IN METAL MODE

Metal can be detected up to 1

1

in. (38 mm) deep

2

in walls and up to 3 in. (77 mm) deep in concrete.

While holding in On/Off

12

button, slowly move unit

on surface, to locate targets.

Reverse directions to locate other

edge of target. Lights will indicate

metal in the same way as in find-

ing studs. When tone sounds,

LEDs light up, and SpotLite comes on, you are close

to metal. Mark this spot to help ensure that you’re

not nailing into a pipe.

CONTINUOUS AC VOLTAGE

DETECTION

The TriScanner Pro SL detects from 90 to 250 V

13

at 50 to 60 Hz AC in a HOT unshielded

electrical wire that is within 1

1

in. (38 mm) of

2

wall surface. The voltage detection feature works

continuously in all modes. The sensor is located in the

center of the back of the unit.

Caution: The TriScanner Pro SL will not detect hot

wires inside metal pipe or metal conduit, behind

metallic wall covering, or behind some plywood or

other dense materials. Use extra caution in these

construction situations. Always turn the power

off when nailing, cutting, or drilling near

electrical wires.

VERIFYING IF THE UNIT WORKS

Turn unit on in the air.

14

If the LEDs light when

you bring your hand up to the

back, then the unit is working

properly.

The AC LED should

15

light with an electrical

cord an inch or two away.

®

Pro SL

®

SpotLite

Pointing System

®

TRISCANNER

PRO SL

this warranty gives you specific legal rights and you may also have other

rights which vary from state to state.

Return product freight prepaid with proof of purchase date (dated sales

receipt) and $5.00 to cover postage and handling, to:

Zircon Corporation

*Attn: Returns Department

2390 Boswell Road, Suite 300

Chula Vista, CA 91914-3510 USA

Be sure to include your name and return address. Out of warranty service and

repair, where proof of purchase is not provided, shall be returned with repairs

charged C.O.D. Allow 4 to 6 weeks for delivery.

Customer Service, 1-800-245-9265 or 1-408-866-8600

Monday–Friday, 8 a.m. to 5 p.m. PST

E-mail: customer.service@zircon.com

U.S. Patent #4464622, 5352974, 5619128, 6023159, 6249113, 6259241,

D419546, D419149, D419545, D427166, and D419544

Canada Patent #1106932 • G.B. Patent #2117909B, 2159630B

©2002 Zircon Corporation • P/N 58756 • Rev B 11/02

OPERATING CAUTIONS

Depending on the proximity of electrical wiring

16

or pipes to the wall surface, the scanner may

detect them in the same manner as studs. Caution

should always be used when nailing, cutting, or

drilling in walls, floors, and ceilings that may contain

these items.

To avoid surprises, remember that studs or joists are

normally spaced 16 in. (406 mm) or 24 in. (610 mm)

apart and are 1

1

in. (38 mm) in width. Anything

2

closer together or a different width may not be a

stud, joist, or firebreak. Always turn off the power

when working near electrical wires.

WORKING WITH DIFFERENT MATERIALS

Wallpaper: TriScanner Pro SL functions normally on

walls covered with wallpaper or fabric, unless the

materials are metallic foil, contain metallic fibers, or

are still wet after application.

Textured Ceilings: When scanning on an uneven

surface, place thin cardboard on ceiling and scan over

the cardboard. Calibrate with cardboard in place.

Note: TriScanner Pro SL cannot scan through

carpeting and pad or, in most cases, lath and plaster.

If you are having difficulty scanning through any of

these or other materials, use the Metal mode to

locate nails in the stud or joist. Try to locate several

nails to get a better idea of how the stud is oriented.

FCC Part 15 Class B Registration Warning

This equipment has been tested and found to comply with the

limits for a Class B digital device, pursuant to Part 15 of FCC

Rules. These limits are designed to provide reasonable protection

against harmful interference when the equipment is operated in

a residential installation. This equipment generates, uses, and

can radiate radio frequency energy and, if not installed and used

in accordance with the instructions, may cause harmful interfer-

ence to radio communications. However, there is no guarantee

that interference will not occur in a particular installation. If this

equipment does cause harmful interference to radio or television

reception, which can be determined by turning the equipment

off and on, the user is encouraged to try to correct the interfer-

ence by one or more of the following measures:

(1) Reorient or relocate the receiving antenna.

(2) Increase the separation between the equipment and receiver.

(3) Connect the equipment into an outlet on a circuit, different

from that which the receiver is connected (if applicable).

(4) Consult the dealer or an experienced radio/TV technician

for help.

INSTALLING THE BATTERY

Press battery door release with a coin and

1

remove door.

Stud Edge

Groove

Connect battery to cable and place inside

2

battery compartment. Replace battery door

LED Sensing

and snap shut. Battery will last approximately two

Display

years under normal conditions.

®

TruCal

LED

TURNING THE POWER ON/OFF

ON: Press and hold ON/OFF button on the left

3

side. OFF: Release ON/OFF button.

Mode Selector

Switch

Note: the Triscanner Pro SL will automatically turn

off after 15 minutes of continuous use (in case

battery button is accidently held down in a toolbox.)

Battery Door

(Back of unit)

SELECTING MODE: STUD SCAN,

STUD DEEPSCAN

®

Use Stud Scan mode for depths to about

(19 mm) and Stud DeepScan for depths up to

1

1

in. (38 mm) or double layers.

2

Slide the Mode selector switch until you reach

4

desired scanning mode. The mode can be

selected with the unit on or off.

CALIBRATING IN STUD SCAN OR

STUD DEEPSCAN MODES

Keep unit flat against wall

during calibration or scanning.

5

Position the TriScanner

Pro SL flat against the

wall. Select mode. Press and

hold On/Off button.

HELPFUL HINTS

Situation

Over-the-Stud Indicator.

• Scan began over a stud.

(Flashing lights)

• Unit not flat against wall.

• Unit tilted or lifted during

Working in DeepScan

• You may have calibrated over

mode and can’t detect

studs.

• You may be holding the unit

Detects other objects

• Electrical wiring and metal/

besides studs in stud

Scan and DeepScan

modes.

You suspect electrical

• If wires are shielded behind

wires, but do not

detect any.

• The wires may not be HOT.

• Wires may be too deep to

Area of voltage

• Static charge may develop on

detection is too large.

Red LEDs light but center

• Wall is particularly thick

pair of green LEDs don’t.

Difficulty detecting

• Unit calibrated over metal.

metal.

• Metal targets are too deep.

Image of metal stud

• Metal has greater density

appears wider than

actual size.

Red LEDs do not light up

• Battery voltage is low.

as you test the unit with

your free hand moving

toward the back of the

TriScanner Pro SL.

Questions? Check our Web site at www.zircon.com and click «Product Support.»

Mode LED and TruCal

6

quickly and then stay lit. TriScanner Pro SL

automatically calibrates in less than one second.

SCANNING IN STUD SCAN OR STUD

DEEPSCAN MODES

Slowly slide unit

7

horizontally across wall,

9 VOLT

BATTERY

left or right.

When center pair of

8

green LEDs light,

steady tone sounds, and the

SpotLite

®

Pointing System

shines, you have found the

stud edge. Mark this spot.

Continue holding

9

On/Off button in and

scan beyond marked spot until

the center green and 3 pairs

of red LEDs go out.

, OR METAL SCAN

Without releasing On/Off

10

3

in.

4

button, slide unit in reverse

direction to locate the other edge

of stud. Mark this second spot.

Middle of stud is centered

between the two marks.

CALIBRATING IN METAL MODE

Select Metal mode. Press

11

and hold ON/OFF button.

Calibrate TriScanner Pro SL in air,

away from metal objects. Position

unit flat against wall.

Probable Causes

• Turn unit off, move over a few inches, and start again.

• Hold unit with thumb and index finger no higher than

handgrips.

scan. (All these factors affect

• On rough surfaces, place a piece of paper on wall,

proper calibration.)

scanning through it to help slide unit more smoothly.

• In Stud Scan or DeepScan modes, hold unit parallel to

and move perpendicular to object you’re trying to locate.

• Move TriScanner Pro SL over a few inches and recalibrate.

a stud. (The error condition is

disabled in DeepScan mode

because it is twice as

sensitive as Stud Scan.)

• Hold the TriScanner Pro SL so that the two Velcro™ strips

like a TV remote, aiming it at

on the back make contact with the wall.

the wall.

• Switch to Metal mode, where combined with continuous

plastic pipes may be near or

AC detection, pipes and electrical wiring should be

touching back surface of

detected adequately.

wall.

• Use CAUTION when nailing, cutting, or drilling in walls,

metallic wall coverings, or in

floors, and ceilings that may contain wiring.

metal conduit, TriScanner Pro

• Use extra caution if the area has plywood, thick wood

SL will not be able to find

backing behind drywall, or thicker than normal walls.

them.

• Remember that studs or joists are normally spaced

16 in. (406 mm) or 24 in. (610 mm) apart and are 1

(38 mm) wide.

sense.

• If a switch controls an outlet, make sure it is ON for detection.

• To narrow detection, turn unit off and on again at the edge

drywall, spreading voltage

of where wire was detected and scan again.

detection as much as 12 in.

• Place free hand flat against wall near tool to discharge

(305 mm) from each side.

static.

• Interpret pair of red LEDs closest to center as stud edge.

or dense.

• Switch to DeepScan to locate the stud.

• Always calibrate in the air for best sensitivity and to avoid

calibrating over metal.

• Scan in both horizontal and vertical directions. Sometimes

metal sensitivity is greater when metal object is parallel to

sensor, which is along top of unit.

• To narrow image, scan and mark first indications and then

than wood and is sensed

calibrate TriScanner Pro SL over either of the first two marks.

farther from edge.

Scan again and mark the new, narrowed detection points.

Repeat if necessary.

• Replace battery to maintain sensitivity.

®

LED will flash

Solutions

1

in.

2

TriScanner

Stud & Metal Locator with AC Warning

The Zircon TriScanner

®

Pro SL

scanner detects wood or metal

studs, metal pipes, and hot

Metal Sensor

electrical wires in interior walls,

floors, and ceilings, as well as

AC LED

rebar in concrete. It features

the SpotLite

®

Pointing System,

Stud Scan

three different scanning modes

Mode LED

plus continuous hot electrical

wire detection.

Stud DeepScan

Mode LED

Metal Scan

Mode LED

On/Off Button

(Side of unit)

LIMITED 1 YEAR WARRANTY

Zircon Corporation, («Zircon») warrants this product to be free from defects

in materials and workmanship for one year from the date of purchase. Any

in-warranty defective product returned to Zircon*, freight prepaid with proof

of purchase date and $5.00 to cover postage and handling, will be repaired or

replaced at Zircon’s option. This warranty is limited to the electronic circuitry

and original case of the product and specifically excludes damage caused by

abuse, unreasonable use or neglect. This warranty is in lieu of all other

warranties, express or implied, and no other representations or claims of any

nature shall bind or obligate Zircon. Any implied warranties applicable to this

product are limited to the one year period following its purchase.

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR

CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR

MALFUNCTION OF THIS PRODUCT.

In accordance with government regulations, you are advised that:

(i) some states do not allow limitations on how long an implied warranty lasts

and/or the exclusion or limitation of incidental or consequential damages, so

the above limitations and/or exclusions may not apply to you, and further (ii)

SCANNING IN METAL MODE

Metal can be detected up to 1

1

in. (38 mm) deep

2

in walls and up to 3 in. (77 mm) deep in concrete.

While holding in On/Off

12

button, slowly move unit

on surface, to locate targets.

Reverse directions to locate other

edge of target. Lights will indicate

metal in the same way as in find-

ing studs. When tone sounds,

LEDs light up, and SpotLite comes on, you are close

to metal. Mark this spot to help ensure that you’re

not nailing into a pipe.

CONTINUOUS AC VOLTAGE

DETECTION

The TriScanner Pro SL detects from 90 to 250 V

13

at 50 to 60 Hz AC in a HOT unshielded

electrical wire that is within 1

1

in. (38 mm) of

2

wall surface. The voltage detection feature works

continuously in all modes. The sensor is located in the

center of the back of the unit.

Caution: The TriScanner Pro SL will not detect hot

wires inside metal pipe or metal conduit, behind

metallic wall covering, or behind some plywood or

other dense materials. Use extra caution in these

construction situations. Always turn the power

off when nailing, cutting, or drilling near

electrical wires.

VERIFYING IF THE UNIT WORKS

Turn unit on in the air.

14

If the LEDs light when

you bring your hand up to the

back, then the unit is working

properly.

The AC LED should

15

light with an electrical

cord an inch or two away.

®

Pro SL

®

SpotLite

Pointing System

®

TRISCANNER

PRO SL

this warranty gives you specific legal rights and you may also have other

rights which vary from state to state.

Return product freight prepaid with proof of purchase date (dated sales

receipt) and $5.00 to cover postage and handling, to:

Zircon Corporation

*Attn: Returns Department

2390 Boswell Road, Suite 300

Chula Vista, CA 91914-3510 USA

Be sure to include your name and return address. Out of warranty service and

repair, where proof of purchase is not provided, shall be returned with repairs

charged C.O.D. Allow 4 to 6 weeks for delivery.

Customer Service, 1-800-245-9265 or 1-408-866-8600

Monday–Friday, 8 a.m. to 5 p.m. PST

E-mail: customer.service@zircon.com

U.S. Patent #4464622, 5352974, 5619128, 6023159, 6249113, 6259241,

D419546, D419149, D419545, D427166, and D419544

Canada Patent #1106932 • G.B. Patent #2117909B, 2159630B

©2002 Zircon Corporation • P/N 58756 • Rev B 11/02

OPERATING CAUTIONS

Depending on the proximity of electrical wiring

16

or pipes to the wall surface, the scanner may

detect them in the same manner as studs. Caution

should always be used when nailing, cutting, or

drilling in walls, floors, and ceilings that may contain

these items.

To avoid surprises, remember that studs or joists are

normally spaced 16 in. (406 mm) or 24 in. (610 mm)

apart and are 1

1

in. (38 mm) in width. Anything

2

closer together or a different width may not be a

stud, joist, or firebreak. Always turn off the power

when working near electrical wires.

WORKING WITH DIFFERENT MATERIALS

Wallpaper: TriScanner Pro SL functions normally on

walls covered with wallpaper or fabric, unless the

materials are metallic foil, contain metallic fibers, or

are still wet after application.

Textured Ceilings: When scanning on an uneven

surface, place thin cardboard on ceiling and scan over

the cardboard. Calibrate with cardboard in place.

Note: TriScanner Pro SL cannot scan through

carpeting and pad or, in most cases, lath and plaster.

If you are having difficulty scanning through any of

these or other materials, use the Metal mode to

locate nails in the stud or joist. Try to locate several

nails to get a better idea of how the stud is oriented.

FCC Part 15 Class B Registration Warning

This equipment has been tested and found to comply with the

limits for a Class B digital device, pursuant to Part 15 of FCC

Rules. These limits are designed to provide reasonable protection

against harmful interference when the equipment is operated in

a residential installation. This equipment generates, uses, and

can radiate radio frequency energy and, if not installed and used

in accordance with the instructions, may cause harmful interfer-

ence to radio communications. However, there is no guarantee

that interference will not occur in a particular installation. If this

equipment does cause harmful interference to radio or television

reception, which can be determined by turning the equipment

off and on, the user is encouraged to try to correct the interfer-

ence by one or more of the following measures:

(1) Reorient or relocate the receiving antenna.

(2) Increase the separation between the equipment and receiver.

(3) Connect the equipment into an outlet on a circuit, different

from that which the receiver is connected (if applicable).

(4) Consult the dealer or an experienced radio/TV technician

for help.

INSTALLING THE BATTERY

Press battery door release with a coin and

1

remove door.

Stud Edge

Groove

Connect battery to cable and place inside

2

battery compartment. Replace battery door

LED Sensing

and snap shut. Battery will last approximately two

Display

years under normal conditions.

®

TruCal

LED

TURNING THE POWER ON/OFF

ON: Press and hold ON/OFF button on the left

3

side. OFF: Release ON/OFF button.

Mode Selector

Switch

Note: the Triscanner Pro SL will automatically turn

off after 15 minutes of continuous use (in case

battery button is accidently held down in a toolbox.)

Battery Door

(Back of unit)

SELECTING MODE: STUD SCAN,

STUD DEEPSCAN

®

Use Stud Scan mode for depths to about

(19 mm) and Stud DeepScan for depths up to

1

1

in. (38 mm) or double layers.

2

Slide the Mode selector switch until you reach

4

desired scanning mode. The mode can be

selected with the unit on or off.

CALIBRATING IN STUD SCAN OR

STUD DEEPSCAN MODES

Keep unit flat against wall

during calibration or scanning.

5

Position the TriScanner

Pro SL flat against the

wall. Select mode. Press and

hold On/Off button.

HELPFUL HINTS

Situation

Over-the-Stud Indicator.

• Scan began over a stud.

(Flashing lights)

• Unit not flat against wall.

• Unit tilted or lifted during

Working in DeepScan

• You may have calibrated over

mode and can’t detect

studs.

• You may be holding the unit

Detects other objects

• Electrical wiring and metal/

besides studs in stud

Scan and DeepScan

modes.

You suspect electrical

• If wires are shielded behind

wires, but do not

detect any.

• The wires may not be HOT.

• Wires may be too deep to

Area of voltage

• Static charge may develop on

detection is too large.

Red LEDs light but center

• Wall is particularly thick

pair of green LEDs don’t.

Difficulty detecting

• Unit calibrated over metal.

metal.

• Metal targets are too deep.

Image of metal stud

• Metal has greater density

appears wider than

actual size.

Red LEDs do not light up

• Battery voltage is low.

as you test the unit with

your free hand moving

toward the back of the

TriScanner Pro SL.

Questions? Check our Web site at www.zircon.com and click «Product Support.»

Mode LED and TruCal

6

quickly and then stay lit. TriScanner Pro SL

automatically calibrates in less than one second.

SCANNING IN STUD SCAN OR STUD

DEEPSCAN MODES

Slowly slide unit

7

horizontally across wall,

9 VOLT

BATTERY

left or right.

When center pair of

8

green LEDs light,

steady tone sounds, and the

SpotLite

®

Pointing System

shines, you have found the

stud edge. Mark this spot.

Continue holding

9

On/Off button in and

scan beyond marked spot until

the center green and 3 pairs

of red LEDs go out.

, OR METAL SCAN

Without releasing On/Off

10

3

in.

4

button, slide unit in reverse

direction to locate the other edge

of stud. Mark this second spot.

Middle of stud is centered

between the two marks.

CALIBRATING IN METAL MODE

Select Metal mode. Press

11

and hold ON/OFF button.

Calibrate TriScanner Pro SL in air,

away from metal objects. Position

unit flat against wall.

Probable Causes

• Turn unit off, move over a few inches, and start again.

• Hold unit with thumb and index finger no higher than

handgrips.

scan. (All these factors affect

• On rough surfaces, place a piece of paper on wall,

proper calibration.)

scanning through it to help slide unit more smoothly.

• In Stud Scan or DeepScan modes, hold unit parallel to

and move perpendicular to object you’re trying to locate.

• Move TriScanner Pro SL over a few inches and recalibrate.

a stud. (The error condition is

disabled in DeepScan mode

because it is twice as

sensitive as Stud Scan.)

• Hold the TriScanner Pro SL so that the two Velcro™ strips

like a TV remote, aiming it at

on the back make contact with the wall.

the wall.

• Switch to Metal mode, where combined with continuous

plastic pipes may be near or

AC detection, pipes and electrical wiring should be

touching back surface of

detected adequately.

wall.

• Use CAUTION when nailing, cutting, or drilling in walls,

metallic wall coverings, or in

floors, and ceilings that may contain wiring.

metal conduit, TriScanner Pro

• Use extra caution if the area has plywood, thick wood

SL will not be able to find

backing behind drywall, or thicker than normal walls.

them.

• Remember that studs or joists are normally spaced

16 in. (406 mm) or 24 in. (610 mm) apart and are 1

(38 mm) wide.

sense.

• If a switch controls an outlet, make sure it is ON for detection.

• To narrow detection, turn unit off and on again at the edge

drywall, spreading voltage

of where wire was detected and scan again.

detection as much as 12 in.

• Place free hand flat against wall near tool to discharge

(305 mm) from each side.

static.

• Interpret pair of red LEDs closest to center as stud edge.

or dense.

• Switch to DeepScan to locate the stud.

• Always calibrate in the air for best sensitivity and to avoid

calibrating over metal.

• Scan in both horizontal and vertical directions. Sometimes

metal sensitivity is greater when metal object is parallel to

sensor, which is along top of unit.

• To narrow image, scan and mark first indications and then

than wood and is sensed

calibrate TriScanner Pro SL over either of the first two marks.

farther from edge.

Scan again and mark the new, narrowed detection points.

Repeat if necessary.

• Replace battery to maintain sensitivity.

®

LED will flash

Solutions

1

in.

2

  • Главная
  • Zircon

  • Детекторы скрытой проводки

  • Pro SL

На этой странице вы найдёте полный список документов на Детекторы скрытой проводки Zircon Pro SL.

Выберите необходимый PDF файл.

  • Детекторы скрытой проводки Zircon Pro SL Инструкция по эксплуатации

    Детекторы скрытой проводки
    Zircon Pro SL Инструкция по эксплуатации

    Тип файла
    PDF

    Размер
    290 Kb

    Кол-во страниц
    1

    Просмотров
    898

    Download / Read online

  • 1

Другие Zircon Детекторы скрытой проводки

  • Zircon MultiScanner Pro SL Руководство по эксплуатации

    PDF файлов
    1

    Просмотров
    10535

  • Zircon TriScanner Pro / Contractor Руководство по эксплуатации

    PDF файлов
    1

    Просмотров
    6657

  • Zircon TriScanner Pro SL Руководство по эксплуатации

    PDF файлов
    1

    Просмотров
    3107

  • Zircon StudSensor Pro SL Руководство по эксплуатации

    PDF файлов
    1

    Просмотров
    2922

  • Zircon iSensor Руководство по эксплуатации

    PDF файлов
    1

    Просмотров
    2526

  • Zircon MetalliScanner MT 6 Руководство по эксплуатации

    PDF файлов
    1

    Просмотров
    2504

Другие устройства Zircon

Вопросы

  • слабая батарея

    Ноутбуки

    Acer

    1310

    Alex 12.02.2016 17:26

Ранее вы смотрели

Производители

Aarrow Fires

Aspects

EarthQuake

JobSite Systems

Lifetime Brands

Maretron

Port-A-Cool

Profoon Telecommunicatie

Sunbeam Major Appliances

Trend Micro

Типы устройств

Камеры видеонаблюдения

Автомобильные динамики

Вентиляторы

Консервные ножи

Пульты оператора

Оборудование для эргономичности рабочего пространства

Гриль и жаровни (электропротивни)

Платформа виртуализации vSpace

Блендер UltimaTM Blender+

Жесткие диски

Устройства

HP X1500 G2 Network Storage System

InFocus RS-232C

LG LSC23924SW

McIntosh MA6300

Mitel Voice First Application 5700

Napoleon Grills PT450RB

Philips 19S1CS/00

Philips AZ2555

Toshiba 55A60R

freeuserguide.ru
About Us
Contacts
Disclamers
Privacy Policy

Эта страница полезна для вас? Поделитесь ссылкой:

Устройство:
Zircon Pro SL

Размер: 0,3 MB

Добавлено: 2014-02-04

Количество страниц: 1

Как пользоваться?

Наша цель — обеспечить Вам самый быстрый доступ к руководству по эксплуатации устройства Zircon Pro SL. Пользуясь просмотром онлайн Вы можете быстро просмотреть содержание и перейти на страницу, на которой найдете решение своей проблемы с Zircon Pro SL.

Для Вашего удобства

Если просмотр руководства Zircon Pro SL непосредственно на этой странице для Вас неудобен, Вы можете воспользоваться двумя возможными решениями:

  • Полноэкранный просмотр -, Чтобы удобно просматривать инструкцию (без скачивания на компьютер) Вы можете использовать режим полноэкранного просмотра. Чтобы запустить просмотр инструкции Zircon Pro SL на полном экране, используйте кнопку Полный экран.
  • Скачивание на компьютер — Вы можете также скачать инструкцию Zircon Pro SL на свой компьютер и сохранить ее в своем архиве. Если ты все же не хотите занимать место на своем устройстве, Вы всегда можете скачать ее из ManualsBase.

Zircon Pro SL Руководство по эксплуатации — Online PDF

Ознакомьтесь с подробным руководством пользователя для замечательного творения Zircon, модель Pro SL. Получите ценную информацию и инструкции, чтобы максимально использовать возможности вашего устройства и оптимизировать взаимодействие с пользователем. Раскройте весь потенциал своего устройства Zircon Pro SL с помощью этого подробного руководства пользователя, в котором содержатся пошаговые инструкции и советы экспертов, которые сделают работу с ним легкой и приятной.

Печатная версия

Многие предпочитают читать документы не на экране, а в печатной версии. Опция распечатки инструкции также предусмотрена и Вы можете воспользоваться ею нажав на ссылку, находящуюся выше — Печатать инструкцию. Вам не обязательно печатать всю инструкцию Zircon Pro SL а только некоторые страницы. Берегите бумагу.

Резюме

Ниже Вы найдете заявки которые находятся на очередных страницах инструкции для Zircon Pro SL. Если Вы хотите быстро просмотреть содержимое страниц, которые находятся на очередных страницах инструкции, Вы воспользоваться ими.

Хорошее руководство по эксплуатации

Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации Zircon Pro SL. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции Zircon Pro SL или обучающее видео для пользователей. Условием остается четкая и понятная форма.

Что такое руководство?

Слово происходит от латинского «instructio», тоесть привести в порядок. Следовательно в инструкции Zircon Pro SL можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.

К сожалению немного пользователей находит время для чтения инструкций Zircon Pro SL, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.

Из чего должно состоять идеальное руководство по эксплуатации?

Прежде всего в инструкции Zircon Pro SL должна находится:
— информация относительно технических данных устройства Zircon Pro SL
— название производителя и год производства оборудования Zircon Pro SL
— правила обслуживания, настройки и ухода за оборудованием Zircon Pro SL
— знаки безопасности и сертификаты, подтверждающие соответствие стандартам

Почему мы не читаем инструкций?

Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск Zircon Pro SL это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок Zircon Pro SL и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта Zircon, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания Zircon Pro SL, как это часто бывает в случае бумажной версии.

Почему стоит читать инструкции?

Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства Zircon Pro SL, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.

После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции Zircon Pro SL. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.

Понравилась статья? Поделить с друзьями:

А вот и еще интересные новости по теме:

  • Инструкция по ремонту мост уаз спайсер
  • Метостабил инструкция по применению цена отзывы аналоги в таблетках
  • Брайт вэй руководство
  • Весел дуэф инструкция цена таблетки отзывы
  • Руководство по хранению продовольственного свежего картофеля

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии