    Operation Installation Diagrams Installing Electrical Connections at the Transmitter Hart Multidrop Installation ® 2.2.1.2 HART Multidrop Installation ® • Unscrew cover from transmitter. • Lift the handle and pull the bucket with the electronics out of the enclosure. • Turn the bucket over and pull off the 5-pin connector. •…
  • Page 3: Installing The Sensor

    Installing the Sensor • Use only Dräger sensors which are designed to be used with the Polytron 2 XP Tox transmitter. • When the sensor is installed, the electronics of the transmitter automatically adjusts to the operating parameters of the sensor.

  • Page 4: Technical Information

    Technical Information Approvals Signal Transmission to Central Control Unit Voltage of Power Supply Physical Specifications Technical Information Approvals UL, CSA ………………….Class I, Div 1, Groups B, C, D ATEX ………………II 2G EEx d [ia] IIC T6 (Ta = -40 to +65°C) II 3D EEx d [ia] IIC T85 (Ta = -40 to +65°C): IP66 CE marking …………

  • Page 5: Environmental Parameters

    Technical Information Environmental Parameters Relay Specification Ambient Influences Environmental Parameters Temperature ………………..–40 to 150 °F (–40 to 65 °C) Pressure ……………… 20.7 to 38.4 in. of Hg (700 to 1300 mbar) Humidity …………………… 0 to 100% RH, transmitter Maximum Air Velocity ………………..≤ 19.5 ft/s (≤ 6 m/s) Relay Specification (Optional) Relays ………………….

  • Page 6: Order Information

    Order Information Calibration Supplies Replacement Parts Order Information Order # Description 4543070 Polytron 2 XP Tox without sensor and relays; UL/ATEX/CSA version 4543200 Polytron 2 XP Tox without sensor, with relays: UL/ATEX/CSA version Calibration Supplies For NAFTA Order # Description Calibration System #1 — for calibration with disposable gas cylinder.

  • Page 7
    Order Information Accessories Accessories For NAFTA Order # Description 4543052 Remote Control, UL, C/UL Version* 4509315 Splash Guard For all other countries Order # Description 4543052 Remote Control, UL, C/UL Version* 6807549 Splash Guard *Replacement batteries “AA” alkaline (IEC Type LR6) of the following type: Panasonic AM3, Duracell MN 1500, Energizer E91, Varta 4006…
  • Page 8
    Certifications…
  • Page 9
    Certifications…
  • Page 10
    Certifications…
  • Page 11
    Certifications…
  • Page 12
    Certifications…

Газоанализатор электрохимический Polytron 2 XP Tox

Газоанализатор электрохимический Polytron 2 XP Tox

Газоанализатор электрохимический Polytron 2 XP Tox
Газоанализатор электрохимический Polytron 2 XP Tox
Газоанализатор электрохимический Polytron 2 XP Tox

Главная / Каталог / Drager / Стационарные газоанализаторы / Снятое с производства оборудование / Газоанализатор электрохимический Polytron 2 XP Tox

Оформить заявку
К сравнению

Газоанализатор Polytron 2 XP Tox предназначен для использования в нефтегазовой промышленности (в наземных и морских приложениях), в химической, автомобильной промышленности и других отраслях, где требуется надежный и точный контроль газов.
Polytron 2 XP Tox непрерывно контролирует содержание токсичных газов и кислорода в окружающем воздухе. Газоанализатор имеет прочный металлический взрывобезопасный корпус, пригодный для внутренних и наружных приложений. Polytron 2 XP Tox можно соединить через герметичный кабелепровод с контрольно-измерительной системой фирмы Dräger или программируемым логическим контроллером (PLC) для выдачи предупреждений об опасных условиях.
При калибровке и настройке Polytron 2 XP Tox может работать с управлением от внутренних кнопок (в неклассифицированных зонах), блока ИК дистанционного управления, или ручного управляющего модуля HART. Блок ИК дистанционного управления или ручной управляющий модуль HART позволяют выполнять калибровку одному человеку без деклассификации зоны. Должным образом настроив реле, которые устанавливаются в прибор по отдельному заказу, газоанализатор можно использовать в автономном режиме.

Файлы

Характеристики

  • ТипВзрывозащищенный газоанализатор для электрохимических сенсоров
  • Измеряемые газыТоксичные газы и кислород
  • Принцип измеренияЭлектрохимический
  • Диапазоны измеренияРегулируются пользователем (см. спецификацию сенсора)
  • ДисплейБольшой графический дисплей. Полнотекстовое представление структуры меню и сообщений
  • Статусный индикаторНет
  • Выходной сигнал Аналоговый (4–20 мА), Цифровой (HART®), сухой контакт (3 реле)
  • Напряжение питания 10–32 В пост. тока; 3-проводное подключение
  • Релейные выходыДва сигнальных реле, одно реле неисправности, 1-полюсные перекидные, программируются пользователем
  • Коммутационная способность 5 А / 240 В пер. тока, 5 А / 24 В пост. тока
  • Условия окружающей среды для датчика газов (для сенсоров см. отдельную спецификацию сенсора)
  • Температура–60 … +65 °C (согласно сертификату соответствия ТР ТС и его приложениям)
  • Давление700–1300 гПа
  • Влажность0–100 %, относительная
  • Корпус датчика газовКрашеный алюминий
  • Класс защиты корпусаIP 67
  • Кабельный ввод3/4 NPT
  • Размеры (ВхШхГ)275 x 130 x 130 мм
  • Вес2,4 кг
  • Уровень SILнет
  • Маркировка взрывозащиты (Таможенный союз)II 2G EEx d [ia] IIC T6/T4
  • Электромагнитная совместимостьДиректива 89/336/EEC
  • Спецификацию заказа см. в кратком описании или руководстве по эксплуатации.

Dräger Polytron 2 XP Tox Transmitter PDF User Guides and Manuals for Free Download: Found (1) Manuals for Dräger Polytron 2 XP Tox Device Model (Operating Manual)

More Transmitter Device Models:

  • Warner RF

    FMT3.0

    Contact:lanyue Email:[email protected] Whatsapp:+86 13602420401 FMT3.0 English Manual The preparation: First of all, please set up the antenna and connect to the transmitter RF OUT port with RF cable。If you need to testing equipment indicators, please pick up the attenuator is greater than 1 kw,attenuat …

    FMT3.0 Transmitter, 7

  • Lodar

    92320

    w92320.09 20 Function and IP Extend Transmitter SYSTEM PART NUMBER 92320 1 x 20 Function Receiver & 1 x 10 Function Extend Transmitter (20 Function in Extend Mode) REPLACEMENT TRANSMITTER 92310TX — 10 Function IP Transmitter with Extend Buttons.(20 Function in Extend Mode) REPLAC …

    92320 Transmitter, 5

  • Camille Bauer

    KINAX N702-SSI

    Camille Bauer Metrawatt AGAargauerstrasse 7CH-5610 Wohlen/SwitzerlandPhone +41 56 618 21 11Fax +41 56 618 21 21 [email protected] Bdfe 157 645-03 01.17 PM1000727 000 01Betriebsanleitung KINAX N702-SSINeigungsaufnehmer mit ölgedämpftemPendelsystemMode d’emploi KINAX N702-SSICapteur d’ …

    KINAX N702-SSI Transmitter, 13

  • HK Instruments

    AVT Series

    Thank you for choosing an HK Instruments AVT Series Air Velocity Transducer. The AVT Series is intended for use in commercial environ-ments. It is designed with a duct mount probe and adjustable collar suitable for round or rectangular ducts. The AVT Series provides separate readings for air velocity and temperature.Th …

    AVT Series Transducer, 4

Recommended Documentation:

  • Home
  • Brands
  • Dräger Manuals
  • Dräger Polytron 2 XP Tox
  • Dräger Polytron 2 XP Tox Operating Manual

Download or browse on-line these Operating Manual for Dräger Polytron 2 XP Tox Transmitter.

Dräger Polytron 2 XP Tox Manual Information:

This manual for Dräger Polytron 2 XP Tox, given in the PDF format, is available for free online viewing and download without logging on.
The guide contains 12 pages, and the size of the file at download is . The document type is Operating Manual.

Download Manual

Summary of Contents:

[Page 1] Dräger Polytron 2 XP Tox

Polytron 2 XP Tox Transmitter for Electrochemical Sensors Operating Manual

[Page 2] Dräger Polytron 2 XP Tox

8 Bucket bottom; electrical connections; HART ® multidrop installation 2.2.1.2 HART ® Multidrop Installation • Unscrew cover from transmitter. • Lift the handle and pull the bucket with the electronics out of the enclosure. • Turn the bucke…

[Page 3] Dräger Polytron 2 XP Tox

18 2.3 Installing the Sensor • Use only Dräger sensors which are designed to be used with the Polytron 2 XP Tox transmitter. • When the sensor is installed, the electronics of the transmitter automatically adjusts to the operating parameters of…

[Page 4] Dräger Polytron 2 XP Tox

53 6 Technical Information 6.1 Approvals UL, CSA …………………………………………………………………………………………… Class I, Div 1, Groups B, C, D ATEX ……………………………………………………..

[Page 5] Dräger Polytron 2 XP Tox

54 6.5 Environmental Parameters Temperature …………………………………………………………………………………… –40 to 150 °F (–40 to 65 °C) Pressure …………………………………………………………..

[Page 6] Dräger Polytron 2 XP Tox

56 8 Order Information Order # Description 4543070 Polytron 2 XP Tox without sensor and relays; UL/ATEX/CSA version 4543200 Polytron 2 XP Tox without sensor, with relays: UL/ATEX/CSA version 8.1 Calibration Supplies For NAFTA Order # Description Cali…

[Page 7] Dräger Polytron 2 XP Tox

57 8.3 Accessories For NAFTA Order # Description 4543052 Remote Control, UL, C/UL Version* 4509315 Splash Guard For all other countries Order # Description 4543052 Remote Control, UL, C/UL Version* 6807549 Splash Guard *Replacement batteries “AA”…

[Page 8] Dräger Polytron 2 XP Tox

58 Certifications

[Page 9] Dräger Polytron 2 XP Tox

59 Certifications

[Page 10] Dräger Polytron 2 XP Tox

60 Certifications

[Page 11] Dräger Polytron 2 XP Tox

61 Certifications

[Page 12] Dräger Polytron 2 XP Tox

62 Certifications

Document’s Content and Additional Information Share Manual

Dräger Polytron 2 XP Tox Operating manual

  • Dräger
  • Transmitter
  • Operating manual for Dräger Polytron 2 XP Tox
  • drager-polytron-2-xp-tox-operating-manual-12_manual.pdf
  • 12 |

Pages Preview:



Document Transcription:

  • 57 8.3 Accessories For NAFTA Order # Description 4543052 Remote Control, UL, C/UL Version* 4509315 Splash Guard For all other countries Order # Description 4543052 Remote Control, UL, C/UL Version* 6807549 Splash Guard *Replacement batteries “AA” alkaline …

  • 61 Certifications

  • 60 Certifications

See Details
Download

Понравилась статья? Поделить с друзьями:

А вот и еще интересные новости по теме:

  • Ланцид инструкция по применению цена аналоги что лучше
  • Администрация тульской области руководство
  • Метро кэш энд керри руководство компании в россии
  • Мануал subaru impreza wrx sti gc8
  • Универсальный пульт для приставки коды инструкция

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии