Измеритель точки росы elcometer 319 инструкция

Elcometer 319 Standard Operating Instructions Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Elcometer 319

Dewpoint Meter

Standard and Top Models

Operating Instructions

loading

Related Manuals for Elcometer 319 Standard

Summary of Contents for Elcometer 319 Standard

  • Page 1
    Elcometer 319 Dewpoint Meter Standard and Top Models Operating Instructions…
  • Page 2
    Bluetooth SIG QDID = B014393. , ElcoShip ® and ElcoMaster ® are registered trademarks of Elcometer Limited. ® and Bluetooth ® are trademarks owned by Bluetooth SIG Inc and licensed to Elcometer Limited. All other trademarks acknowledged. © Copyright Elcometer Limited 2009-2010.
  • Page 3: Table Of Contents

    CONTENTS Section Page About your gauge …………. . 2 Quick start .

  • Page 4: About Your Gauge

    The Elcometer 319 Dewpoint Meter is a world beating product. With the purchase of this gauge you now have access to the worldwide service and support network of Elcometer. For more information visit our website at www.elcometer.com.

  • Page 5
    1.1 FEATURES Model Feature page Standard User-adjustable high and low limits for all parameters + alarm Trend indicators on all parameters User-configurable display with large easy-to-see main reading Multiple languages Built-in high power magnets to attach the gauge to ferrous objects Statistical analysis of readings Individual readings review Date and time stamping of all reading data…
  • Page 6
    Please consult your local Environmental Authority for further guidance. To maximise the benefits of your new Elcometer 319 Dewpoint Meter please take some time to read these Operating Instructions. Do not hesitate to contact Elcometer or your Elcometer supplier if you have any questions.
  • Page 7: Quick Start

    2 QUICK START see page 22 see page 19 see page 16 see page 26 Note: ‘Batch’ is displayed on [T] models only…

  • Page 8: Getting Started

    3 GETTING STARTED 3.1 POWER SUPPLY Your gauge is powered by batteries or by a USB cable when it is connected to a computer. An icon in the top right of the display indicates which power supply is being used Attention: The USB power supply cannot be used to charge batteries.

  • Page 9
    FITTING BATTERIES The batteries are located under the cover at the rear of the gauge. To replace the batteries, remove the retaining screw and the cover and fit high quality alkaline dry batteries (2x AA / LR6) taking care to ensure correct battery polarity.
  • Page 10
    3.2 THE CONTROLS Your gauge is controlled by five keys: • Upper row of four keys: These are Softkeys whose function changes according to the text and symbols on the bottom row of the display. • Lower single key: Press to switch the gauge on; press and hold to switch off (also see “Auto Switch Off”…
  • Page 11
    3.5 THE SENSORS The sensors for humidity, air temperature and surface temperature are Surface located at the top of the gauge. temperature Note: The surface temperature sensor is flexibly mounted. This will reduce Air temperature the risk of damage if the gauge is dropped. and humidity FOR ACCURATE READINGS •…
  • Page 12
    3.6 THE READING SCREEN While the instrument is measuring, the display may show the following information and symbols. Refer to the page number (xx) for more information: Parameter (25) Trend — value Alarm (21) increasing/ decreasing (13) Battery power & USB power [T] (7) condition (7) Bluetooth enabled [T] (24)
  • Page 13
    Main Reading — see page 25. To increase the size of the Main Reading, reduce the number of parameters displayed on the reading screen (the illustrations shows reading screens from the Elcometer 319 Top model).
  • Page 14
    3.7 THE MENUS MENU SETUP TIME & DATE Delete Last Reading Units Set Time & Date Backlight Languages Set Date Format SET DATE FORMAT Thermometer Mode Auto Switch Off DD/MM/YYYY Set Limits Time & Date MM/DD/YYYY DISPLAY View Time & Date Beep Volume YYYY/MM/DD Select Readings…
  • Page 15: Taking Readings

    Follow this procedure to take readings manually with the option to save your reading data into the rolling memory of your gauge. Users of the Elcometer 319 Top model can also save reading data into batch memory [T] — see page 14. Before you start: •…

  • Page 16
    4.2 SAVING READING DATA INTO BATCH MEMORY [T] Follow this procedure to take readings manually (manual logging) or automatically at set time intervals (interval logging) and log the reading data into a batch in your gauge memory. Before you start, if you intend to take measurements over a long period of time: •…
  • Page 17
    4. To save your reading data into the batch: • Manual logging: Press Save or Hold>Save (depending upon the Manual Logging [T] setting — see page 26) • Interval logging: Your reading data are saved automatically at the set interval. 5.
  • Page 18: Batching [T]

    5 BATCHING [T] This section describes the functions available by pressing Batch from the reading screen. Note: When a batch is already open, the Batch softkey is replaced by To access or initiate a function, scroll to the required function and press Sel. To return immediately to the reading screen at any stage, press and hold Back/Esc.

  • Page 19
    If a delayed start time is set, is displayed during this time period. Logging starts after the delayed start time, is displayed and readings are taken at the set interval. To return to the Batch menu, press Esc. Open Existing Batch: Opens an existing batch ready to input more data by manual or interval logging.
  • Page 20
    The Review Batch screen is displayed. The screen lists: Batch number, number of readings, date and time batch was created, date and time of last reading, batch type and interval (interval logged batches only). To view the statistics for the batch, press Stats (see “Statistics” on page 19). To view the readings for the batch, press Rdgs.
  • Page 21: Statistics

    6 STATISTICS Your gauge can display a statistical analysis of reading data saved into the rolling memory of your gauge. Users of the Elcometer 319 Top model can also display a statistical analysis of reading data logged into batch memory [T].

  • Page 22
    CLEARING STATISTICS AND READING DATA IN ROLLING MEMORY 1. With the reading screen displayed, press Stats. The statistics are displayed. 2. Press Clear and then press Yes to confirm or No to decline. 6.2 STATISTICS AND THE BATCH MEMORY [T] VIEWING STATISTICS AND READING DATA IN BATCH MEMORY (Manual Logging or Interval Logging with Stats displayed) 1.
  • Page 23: Limits

    6.3 STATISTICS VALUES The statistics calculated by your gauge are given in Table 1. Table 1: Calculated statistics values Number of Readings The current number of sets of reading data saved in a batch. The average of a group of readings; the sum of the individual Mean readings divided by the number of readings.

  • Page 24: The Menu

    • the parameter icon flashes (even if it has been deselected to be shown on the display) • an alarm symbol is displayed next to the parameter. • if the readings are being logged into batch memory [T] a reading which exceeds a high limit is marked and a reading which exceeds a low limit is marked by When the value of the parameter returns within limits the alarm status is cleared automatically.

  • Page 25
    temperature probe is not fitted when Thermometer Mode is toggled ‘on’, the gauge will display an error reading ‘—’. Set Limits: Toggles limits on/off and adjusts limits for all measured and calculated parameters. The Set Limits menu is displayed. Any low and high limit values toggled ‘on’ are listed. To toggle a limit on/off or adjust its value, scroll to the parameter and press Sel.
  • Page 26: Gauge Setup

    To view the information, scroll to the parameter of choice and press Sel. Gauge Information — Elcometer model #, gauge identity, language, language version, software versions Contact — details of Elcometer offices worldwide and, if applicable, the contact details for the supplier or local distributor.

  • Page 27
    To select the language, scroll to the required language and press Sel. Auto Switch Off: Select the time delay before your gauge switches off automatically. To select the time delay, scroll to the required value (Off, 1 minute to 10 minutes) and press Ok. To return to the Setup menu, press Esc.
  • Page 28
    Note: If a reading exceeds limits during measurement, it will be shown flashing on the display, even if it has been deselected from the list of reading shown on the display. Manual Logging [T]: Select how readings are saved when taking readings manually (manual logging). The Manual Logging menu is displayed.
  • Page 29: Using External Temperature Probes

    To adjust the brightness of the backlight, scroll to Backlight Brightness and press Sel. Scroll to the brightness required (Low, Medium, High) and press Sel. When finished, press Back. 10 USING EXTERNAL TEMPERATURE PROBES Your gauge can be fitted with an external temperature probe. An external probe is used typically for taking measurements: •…

  • Page 30: Transferring Readings To A Computer [T]

    10.2 PREPARING YOUR GAUGE FOR USE WITH AN EXTERNAL PROBE Attention: The external temperature probe can be capable of measuring temperature in excess of the physical operating range of the gauge. When using your gauge with an external temperature probe, take care to avoid exposing your gauge to excess temperatures.

  • Page 31
    ElcoMaster and ElcoMaster Mobile are on the CD supplied with your gauge and they can also be downloaded, together with any subsequent upgrades, from the Elcometer website www.elcometer.com Your gauge is also fully compatible with ElcoShip — see www.elcoship.com for further details.
  • Page 32: Personalised User Screen

    11.3 TRANSFERRING READING DATA USING A BLUETOOTH CONNECTION 1. Switch on your gauge and ensure the Reading Screen is displayed. 2. Enable Bluetooth communications — see “Bluetooth [T]” on page 24. When Bluetooth is enabled, a Bluetooth symbol is displayed on the right side of the display. During transfer of data between your gauge and your PC, the Bluetooth symbol flashes.

  • Page 33: Maintenance

    Display of the user screen can be toggled ‘on’ or ‘off’ (Menu>Setup>User Screen) — see “User Screen” on page 26. 12.1 CREATING THE USER SCREEN 1. Install and run ElcoMaster software. 2. Connect the gauge to the PC using the USB cable (optional equipment for [S] gauges) or Bluetooth [T].

  • Page 34
    Elcometer supplier. Your gauge does not contain any user-serviceable components. In the unlikely event of a fault, the gauge should be returned to your Elcometer supplier or directly to Elcometer. The warranty will be invalidated if the gauge has been opened.
  • Page 35: Spare Parts And Accessories

    14 SPARE PARTS AND ACCESSORIES The following spare parts and accessories are available from your local Elcometer supplier or direct from Elcometer: External Temperature Probe — Surface Mount, Magnetic T31920162 External Temperature Probe — Liquids T9996390- Protective Pouch T99921192 USB Cable…

  • Page 36
    This variation may be greater than ±1°C for Twb and ±1%/10mb for SH. OPERATING RANGE • Surface temperature (built-in probe) -20°C to 80°C (-4°F to 176°F) • External temperature (Elcometer external probe)Ts -40°C to 200°C (-40°F to 392°F) • Air temperature -20°C to 80°C (-4°F to 176°F) •…
  • Page 37
    • Relative humidity 0.1% • Specific humidity 0.1 g/kg (0.1gr/lb) MEMORY • Rolling 10 sets of readings • Batch [T] Up to approximately 36 000 sets of readings in up to 999 batches PHYSICAL • Gauge dimensions 174 mm x 75 mm x 35 mm (6.8” x 3” x 1.4”) •…
  • Page 38: Related Equipment

    16 RELATED EQUIPMENT In addition to the Elcometer 319 Dewpoint Meter, Elcometer produces a wide range of other climatic condition monitoring equipment and associated paint inspection equipment. Users of the Elcometer 319 Dewpoint Meter may also benefit from the following Elcometer products: •…

  • Page 39: Index

    Selecting Interval or Manual Adjusting Display Protection Film Batching Batteries Condition indicator Keys Fitting ElcoMaster Maximising life Personalised user screen Battery life Elcometer Language, choosing Beep Volume Addresses in gauge Lights Bluetooth ElcoShip Limits Configuring Exit Batching Setting Transferring readings…

  • Page 40
    Manual Logging Mean Saving reading data Units, choosing Measuring Into batch memory USB Cable Memory Into rolling memory Spare Batch Sensors USB power supply Rolling Set Delayed Start User screen Menu 12, 22 Set Interval Creating Mobile devices, transferring data Setup Switching on/off Setup Backlight…

This manual is also suitable for:

319 top

(Ocr-Read Summary of Contents of some pages of the Elcometer 319 Standard Document (Main Content), UPD: 17 February 2023)

  • 8, 6 R 3 GETTING STARTED 3.1 Fitting batteries Alkaline batteries must be disposed of carefully to avoid environmental contamination. Please consult your local Environmental Authority for information on disposal in your region. Do not dispose of any battery in fire. The condition of the batteries is indicated by a symbol on the display — see “What the symbols mean” on page 8. To retain time and date, fit new batteries within 30 seconds of removal of the exhausted batteries. Always…

  • 6, 4 R The Elcometer 319 Dewmeter is packed in a cardboard and foam package. Please ensure that this packaging is disposed of in an environmentally sensitive manner. Please consult your local Environmental Authority for further guidance. To maximise the benefits of your new Elcometer 319 Dewmeter please take some time to read these Operating Instructions. Do not hesitate to contact Elcometer or your Elcomet…

  • 11, Elcometer 319 Standard 9 R Temper- ature Reading of temperature in °C or °F. Temperature type is shown by the symbol below. Temper- ature type Ambient Surface Dewpoint Delta T (∆T) Date a dd.mm.yy (when set to °C) mm.dd.yy (when set to °F) a.The bottom line of the display displays other information when accessing memory and gauge set up. C F %Rh men u alarm link C F %Rh men u alarm link C F %Rh men u alarm link

  • 20, 18 R 9 DATA TRANSFER SOFTWARE (EDTS + ) Use EDTS + Excel Link for quick and easy transfer of data from the memory of your gauge into a Microsoft Excel spreadsheet. To use the software you will need an interface cable and EDTS + software. The cable is available from your local Elcometer supplier or directly from Elcometer. The software is available free of charge from the downloads section of the Elcometer website www.elcometer.com EDTS + can be used on computers oper…

  • 24, 22 R 14 RELATED EQUIPMENT In addition to the Elcometer 319 Dewmeter, Elcometer produces a wide range of other climatic condition monitoring equipment and associated paint inspection equipment. Users of the Elcometer 319 Dewmeter may also benefit from the following Elcometer products: • Elcometer Surface Profile Gauges and Testers • Elcometer Surface Cleanliness Test Kits • Elcometer Moisture Meters • Elcometer Wet Film an…

  • 3, 1 R CONTENTS Section Page 1 About your gauge ………………………………2 1.1 Climatic conditions . . . . . . . . . . . . . . . . . . 3 1.2 Standards . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.3 What the box contains . . . . . . . . . . . . . . . 3 2 Quick start …………………………………………5 3 Getting started …………………………………..6 3.1 Fitting batteries . . . . . . . . . . . . . . . . . . . . . 6 3.2 Swi…

  • 19, 17 R To access gauge set up: Press Display shows Settings 1. MEMORY oFF 2. set up 3. a a.If you do not want to change a setting, press to skip to the next parameter. CYCLE b b.Cycle: Values shown on display change automatically (ambient > surface > dewpoint > ∆T). 0=no change, 1=1 second interval, etc. 0 — 10 4. YEAR c c.Year: 0=2000, 99=2099, etc. 0 — 99 5. MONTH 1 — 12 6. DAY 1 — 31 7. HOUR 0 — 23 8. MINUTE 0 — 10 9. UNITS d d.…

  • 15, Elcometer 319 Standard 13 R 7.4 Printing readings The stored data can be printed on the (optional) HP-IR printer: All stored Datasets will be sent to the printer. Printing can be stopped at any time by pressing . 6. or Readings in dataset 7. a.If RECALL does not appear, memory is empty. b.XX = dataset number (1- 99). Press Display shows 1. MEMORY oN 2. RECALL a a.If RECALL does not appear, memory is empty. 3. PRINT 4. Place the gauge in front of the HP-IR printer at a distance of about 10 cm (4”). Ma…

  • 10, Elcometer 319 Standard 8 R 3.4 What the symbols mean Menu Indicates that the display is showing menu information, not readings. Alarm Indicates that ∆T is less than 3°C. When ∆T rises above 3.5°C, the alarm switches off. Link Indicates that memory is on. Press twice to store a reading while memory is on. Battery status 4 segments: Full 1 segment: Empty Flashing: Change battery now Relative humidity Time C F %Rh alarm linkmen u C F %Rh men u alarm l…

  • 5, 3 R 1.1 Climatic conditions The risk of condensation forming on surfaces about to be coated is always present and is difficult to assess without suitable instruments. In particular, it is difficult to detect condensation on blast cleaned surfaces. Surfaces with a temperature at or below this dewpoint temperature will be covered with condensation/moisture. It is important to take measurements at regular interv…

  • 22, Elcometer 319 Standard 20 R 11 SURFACE TEMPERATURE PROBES A range of alternative probes is available to connect in place of the standard surface probe. To use these optional external temperature probes, the surface probe has to be removed from the gauge by gently pulling the surface probe by its plastic housing. The optional external probes must be connected in the same way as the standard surface probe. Always make sure to align the probe connector cor…

  • 2, English R The Elcometer 319 Dewmeter has been tested in accordance with EU regulations governing electro- magnetic compliance and meets the required directives. Note: Gauge readings may be affected if the unit is operated within a radio frequency electromagnetic strength of greater than3 V/m. is a registered trademark of Elcometer Instruments Ltd. All other trademarks acknowledged. © Copyright Elcometer Instruments Ltd. 2001 — 2006. Al…

  • 13, 11 R 6 TAKING A READING 1. Hold the gauge with the probe in the area to be measured. If you are measuring surface temperature, hold the gauge with the tip of the probe in contact with the surface to be measured. For good contact, hold the gauge perpendicular to the surface. 2. Use the arrow buttons and to select the parameter required (ambient, surface, dewpoint or ∆T). Relative humidity and the selected temp…

  • 12, 10 R 4 THE SENSORS The sensors for humidity, air temperature and surface temperature are located in the probe at the top of the gauge. For accurate readings: • Do not obstruct airflow through the slots in the probe around the humidity and temperature sensors. • Keep your fingers away from the slots — the heat from your body may affect readings. • Allow the gauge some time to acclimatise once it is brought from a cold environment into a warm place or vice versa. To avoid damage: When measu…

  • 14, 12 R 7.1 Switching memory on To use the memory in your gauge, the memory must be switched ‘on’. If the link symbol is visible on the display, the memory is already switched on. If the link symbol is not visible: Memory is now switched on and ready for storage, recall, printing and export of readings. 7.2 Storing a reading To store a reading in memory, press the button twice. The display will show which memory l…

  • 17, 15 R 7.6 Clearing (deleting) readings To clear b the stored data from the memory: The most recent dataset will be deleted. To delete all datasets quickly, press and hold . When all Datasets have been cleared or is pressed, the gauge returns to the measurement mode. Press Display shows 1. MEMORY oN 2. RECALL a a.If RECALL does not appear, memory is empty. 3. x 3 CLEAR 4. b. Data that have been cleared are pe…

  • 21, 19 R 10 MAINTENANCE You own one of the finest dewpoint meters in the world. If looked after, it will last a lifetime. Regular calibration checks over the life of the gauge are a requirement of quality management procedures, e.g. ISO 9000, and other similar standards. For checks and certification contact Elcometer or your Elcometer supplier. Your gauge does not contain any user- serviceable components. In the unlikely event of a faul…

  • 7, 5 R 2 QUICK START 1. Fit batteries (see page 6). 2. Press to switch on. 3. Humidity and Temperature are shown on the display. 4. If required, press or to change the type of temperature displayed: To learn how to store readings in memory, see “Using your gauge memory” on page 11. To learn how to set up your gauge, see “Gauge set up” on page 16. Ambient Surface Dewpoint Delta T ON C F %Rh menu alarm link Temperature Humidity Temperature type …

Измеритель точки росы Elcometer 319

Измеритель точки росы Elcometer 319 – универсальный прибор для измерения всех климатических параметров влияющих на пригодность поверхности к покраске и нанесению изоляции. В зависимости от модификации прибор можно использовать в ручном режиме или как удаленный регистратор с передачей данных на ПК и мобильные устройства Apple и Android.

Измеритель имеет встроенные магниты для крепления на стальных поверхностях. Корпус и датчики защищены от пыли и влаги по стандарту IP 66. Предусмотрена визуальная и звуковая индикация превышения установленных значений по одному или нескольким параметрам. С версией T возможна регистрация до 25 000 наборов данных в 999 папках. Для каждого набора данных возможна запись времени и даты. Версия T поставляется с программой Elcomaster 2.0 для анализа данных и составления профессиональных отчетов.

Elcometer 319 обеспечивает измерение следующих климатических параметров:

  • относительная влажность (RH),
  • TΔ — разность между температурой поверхности и точкой росы (TΔ),
  • температура воздуха (Ts),
  • температура поверхности (Ta),
  • температура сухого термометра (Tdb),
  • температура точки росы (Td),
  • температура влажного термометра (Twb).

Измеритель имеет встроенные магниты для крепления на стальных поверхностях. Корпус и датчики защищены от пыли и влаги по стандарту IP 66. Предусмотрена визуальная и звуковая индикация превышения установленных значений по одному или нескольким параметрам. С версией T возможна регистрация до 25 000 наборов данных в 999 папках. Для каждого набора данных возможна запись времени и даты. Версия T поставляется с программой Elcomaster 2.0 для анализа данных и составления профессиональных отчетов.

Elcometer 319 внесен в Госреестр средств измерений РФ (№ 56757-14). Методика поверки содержится в МП 56757-14. В стандартный комплект поставки входит заводской сертификат о калибровке. Свидетельтсво о поверке РФ поставляется по заявке. Производство Elcometer – Великобритания. Срок гарантии и межповерочный интервал 12 месяцев. Прибор соответствует требованиям ГОСТ 8.585-2001, ГОСТ 30732-2006, ГОСТ 9.402-2004, EN ISO 8502-3,

Измеритель точки росы Elcometer 319Измеритель точки росы Elcometer 319Измеритель точки росы Elcometer 319Измеритель точки росы Elcometer 319Измеритель точки росы Elcometer 319Измеритель точки росы Elcometer 319

Технические характеристики измерителя точки росы Elcometer 319

Технические характеристики Модель S Модель Т
Измеряемые параметры — RH, Ta, Ts, Td, TΔ, Tdb, Twb, SH1
Рассчитываемая статистика – количество измерений, стандартное отклонение, коэффициент вариации, минимальное, максимальное значение
Пыле и брызгозащищенный корпус с полностью герметичными датчиками – защита по стандарту IP 66
Встроенные магниты для крепления прибора в режиме регистратора данных
Верхний/нижний пределы измерения – аудиовизуальная сигнализация, подсказки красным/зеленым LED индикатором могут быть установлены для любого или всех параметров
Многоязыковое меню
Настраиваемая подсветка
Разъем типа K для подключения внешних датчиков
Память с просмотром результатов и статистики измерений Последние 10 показаний 25000 наборов данных в 999 группах
Режим ручной регистрации данных
Режим автоматической регистрации через интервалы времени с настройкой интервала2   Интервал от 1 секунды до 1 часа
Вывод данных: USB и беспроводное соединение Bluetooth  
Программное обеспечение ElcoMaster & ElcoMaster Mobile  
  Диапазон температур Точность Разрешение
Прибор# -40 – +200ºC ±0,5ºC 0,1ºC
Температура воздуха (Ta): -20 – +80°C ±0,5°C 0,1°C
Температура поверхности (Ts): -20 – +80°C ±0,5°C 0,1°C
Внешняя термопара типа К (Te)#: -20 – +80ºC ±2,0°C+ 0,1°C
Относительная влажность (RH): 0 – 100% RH ±3% RH 0,1%
Рабочий диапазон температур прибора и ЖК-дисплея: -20°C – +80°C    
Питание: 2 батареи типа AA 1,5В или через кабель USB
Срок службы батарей: Ручной режим: Более 40 часов (подсветка отключена)

Режим регистрации через интервалы: до 400 часов (1 измерение каждые 10 минут)

Размеры: 180 x 75 x 35 мм
Вес: 300 г
Доступные сертификаты: Сертификат калибровки производителя Elcometer Limited

Комплект поставки:

  • измеритель точки росы Elcometer 319,
  • 2 батареи типа АА,
  • ремешок на запястье,
  • чехол для переноски,
  • калибровочный сертификат производителя,
  • кабель USB (только модель T),
  • программное обеспечение ElcoMaster™ & ElcoMaster™ Mobile Software (только модель T),
  • Elcometer 319 – инструкция по эксплуатации.

Видео — демонстрация возможностей Elcometer 319

Подпишитесь на наш канал YouTube

Дополнительная информация:

  • Описание типа средств измерения — Elcometer 319
  • Описание прибора на сайте производителя

Профилемер поверхности Elcometer 224 можно купить с доставкой до двери или до терминалов транспортной компании в следующих городах: Москва, Санкт-Петербург, Екатеринбург, Саратов. Амурск, Ангарск, Архангельск, Астрахань, Барнаул, Белгород, Бийск, Брянск, Воронеж, Великий Новгород, Владивосток, Владикавказ, Владимир, Волгоград, Волгодонск, Вологда, Иваново, Ижевск, Йошкар-Ола, Казань, Калининград, Калуга, Кемерово, Киров, Кострома, Краснодар, Красноярск, Курск, Липецк, Магадан, Магнитогорск, Мурманск, Муром, Набережные Челны, Нальчик, Новокузнецк, Нарьян-Мар, Новороссийск, Новосибирск, Нефтекамск, Нефтеюганск, Новочеркасск, Нижнекамск, Норильск, Нижний Новгород, Обнинск, Омск, Орёл, Оренбург, Оха, Пенза, Пермь, Петрозаводск, Петропавловск-Камчатский, Псков, Ржев, Ростов, Рязань, Самара, Саранск, Смоленск, Сочи, Сыктывкар, Таганрог, Тамбов, Тверь, Тобольск, Тольятти, Томск, Тула, Тюмень, Ульяновск, Уфа, Ханты-Мансийск, Чебоксары, Челябинск, Череповец, Элиста, Ярославль и другие города, кроме того, в Республике Крым. А также Республики Казахстан, Белоруссия и другие страны СНГ.

319.jpg Описание прибора

Данный надёжный прибор разработан для измерения и регистрации всех климатических параметров, требуемых для определения пригодности поверхности к покраске. Elcometer 319 может использоваться как ручной измерительный прибор или как автономный регистратор данных — идеально подходящий для мониторинга условий окружающей среды в течение требуемого периода времени.

Особенности прибора

  • Встроенные магниты позволяют проводит удаленный контроль условий окружающей среды на стальных основаниях.
  • Сохраняет до 25000 наборов данных в 999 группах памяти
  • Вывод данных через USB и Bluetooth на ПК и планшеты.
  • Пыле и брызгозащищенный корпус с полностью герметичными датчиками — защита по стандарту IP66
  • Визуальная и звуковая индикация выхода за определенных пользователем пределы для любого или всех измеряемых параметров
  • Многоязыковое меню с интуитивно-понятной структурой
  • Портативный измеритель точки росы с ручной и автоматической регистрацией данных в одном приборе
  • Большой дисплей с настраиваемой подсветкой работает во всём диапазоне рабочей температуры прибора.
  • Измерение и регистрация следующий климатических параметров:319painttin.jpg

            — Относительная влажность (RH)
            — Температура воздуха (Ta)           
            — Температура поверхности (Ts)
            — Температура точки росы (Td)
            — TΔ (Дельта Т) разность между температурой поверхности
               и точкой росы (TΔ)
            — Температура сухого термометра (Tdb)
            — Температура влажного термометра (Twb)

Точность

  • Соответствует стандарту ISO 8502-4
  • Быстрое время отклика
  • Каждый прибор поставляется с калибровочным сертификатом производителя
  • Переключение между единицами измерения Цельсия и Фаренгейта319display.jpg
  • Запись времени и даты для каждого набора данных
  • Простота
  • Простой интерфейс, управляемый с помощью многоязычного меню
  • Четкий дисплей с подсветкой, позволяющий одновременно отображать значения до 5 параметров из списка ниже:
    — Относительная влажность (RH) — TΔ (Дельта Т)
    — Температура воздуха (Ts) — Температура сухого термометра (Tdb)
    — Температура поверхности (Ta) — Температура влажного термометра (Twb)
    — Температура точки росы (Td) — Удельная влажность (SH)
  • Стрелочные индикаторы температуры указывают направления изменения температуры

Гибкость 319ibar.jpg

  • Использование прибора как портативного измерителя точки росы или как удаленного регистратора данных климатических условий (только модель Т)
  • Встроенный разъем типа К позволяет измерять температуру поверхности во время удаленной регистрации данных
  • Режим «Te» превращает прибор в простой термометр — идеально для измерения температуры покрытия перед нанесением или температуры внешних объектов
  • Функция удержания позволяет просмотреть отдельные показания перед записью в память.

 Долговечность

  • Изготовлен из стойких к воздействию температур материалов, что позволяет использование при температурах от -20°C до +80°C
  • Защита корпуса от брызг и пыли по стандарту IP66
  • Прочная и эргономичная конструкция корпуса дополняется долговечными промышленными датчиками, выдерживающими тяжелые условия эксплуатации
  • Четкий дисплей с подсветкой работает во всём диапазоне рабочей температуры прибора.

Универсальность

  • Данные могут быть переданы в ПК через интерфейсы USB или Bluetooth и обработаны при помощи программного обеспечения ElcoMaster 2.0.
  • ПО ElcoMaster имеет уникальную функцию «Watchguard», позволяющую пользователю удаленно следить за показаниям до 42 приборов на одном экране (только моделей Т)
  • Любой прибор может питаться от 2 батарей типа AA (до 400 часов работы) или напрямую от порта USB.
  • Установка пределов измерения для каждого измеряемого параметра; при выходе параметра за пределы включается аудиовизуальная сигнализация, даже если он не отображается на дисплее.

Технические характеристики

Модель Модель S Модель Т
Код заказа G319—-S G319—-T
Измеряемые параметры — RH, Ta, Ts, Td, TΔ, Tdb, Twb, SH1
Рассчитываемая статистика — количество измерений, стандартное отклонение, коэффициент вариации, минимальное, максимальное значение
Пыле и брызгозащищенный корпус с полностью герметичными датчиками — защита по стандарту IP66
Встроенные магниты для крепления прибора в режиме регистратора данных
Верхний/нижний пределы измерения — аудиовизуальная сигнализация, подсказки красным/зеленым LED индикатором могут быть установлены для любого или всех параметров
Многоязыковое меню
Подсветка дисплея — настраиваемая пользователем
Разъем типа K для подключения внешних датчиков
Память с просмотром результатов и статистики измерений Последние 10 показаний 25000 наборов данных в 999 группах
Режим ручной регистрации данных
Режим автоматической регистрации через интервалы времени с настройкой интервала2 Интервал от
1 секунды до
1 часа
Вывод данных: USB и беспроводное соединение Bluetooth
Программное обеспечение ElcoMaster & ElcoMaster Mobile
Диапазон температур Точность Разрешение
Прибор#: -40 — +200ºC

±0,5ºC

0,1ºC
Температура воздуха (Ta): -20 — +80°C ±0,5°C 0,1°C
Температура поверхности (Ts): -20 — +80°C ±0,5°C 0,1°C
Внешняя термопара типа К (Te)#: -20 — +80ºC ±2,0°C+ 0,1°C
Относительная влажность (RH): 0 — 100% RH ±3% RH 0,1%
Рабочий диапазон температур прибора и ЖК дисплея: -20°C — +80°C
Питание: 2 батареи типа AA 1,5В или через кабель USB
Срок службы батарей: Ручной режим:Более 40 часов (подсветка отключена)
Режим регистрации через интервалы: до 400 часов                           (1 измерение каждые 10 минут)
Размеры: 180 x 75 x 35 мм
Вес: 300 г
Доступные сертификаты: Сертификат калибровки производителя Elcometer Limited (поставляется бесплатно в комплекте с прибором)
Комплект поставки: Измеритель точки росы Elcometer 319, 2 батареи типа АА, ремешок на запястье, чехол для переноски, калибровочный сертификат производителя, кабель USB*, программное обеспечение ElcoMaster™& ElcoMaster™Mobile Software*, инструкция по эксплуатации

# Не подвергайте прибор воздействие температур, находящихся вне диапазон рабочих температур прибора и ЖК дисплея.
* Только модель T
+ Точность ±2°C с термопарой типа К, поставляемой Elcometer. Точность с другими датчиками может отличаться.
1 Рассчитываемое значение

2 С датчиком T31920162

Может использоваться в соответствии со следующими Стандартами:
BS 7079-B4, IMO MSC.215(82), IMO MSC.244(83), ISO 8502-4, US Navy NSI 009-32, US Navy PPI 63101-000

Версия для печати

Измеритель точки росы Elcometer 319 – термогигрометр для определения относительной и удельной влажности, температуры воздуха (NTC: -20 — +80°C) и поверхности (K: -20 — +80ºC), температуры сухого и влажного термометра и температуры точки росы.

Термогигрометр Elcometer 319 разработан для измерения и регистрации всех климатических параметров, требуемых для определения пригодности поверхности к покраске. Elcometer 319 может использоваться как ручной измерительный прибор или как автономный регистратор данных — идеально подходящий для мониторинга условий окружающей среды в течение требуемого периода времени.

  • Встроенные магниты позволяют проводит удаленный контроль условий окружающей среды на стальных основаниях.
  • Сохраняет до 25000 наборов данных в 999 группах памяти
  • Вывод данных через USB и Bluetooth на ПК и планшеты.
  • Пыле и брызгозащищенный корпус с полностью герметичными датчиками — защита по стандарту IP66
  • Визуальная и звуковая индикация выхода за определенных пользователем пределы для любого или всех измеряемых параметров
  • Многоязыковое меню с интуитивно-понятной структурой
  • Портативный измеритель точки росы с ручной и автоматической регистрацией данных в одном приборе
  • Большой дисплей с настраиваемой подсветкой работает во всём диапазоне рабочей температуры прибора.
  • Измерение и регистрация следующий климатических параметров:
    • Относительная влажность (RH)
    • Температура воздуха (Ta)
    • Температура поверхности (Ts)
    • Температура точки росы (Td)
    • TΔ (Дельта Т) — разность между температурой поверхности
      и точкой росы (TΔ)
    • Температура сухого термометра (Tdb)
    • Температура влажного термометра (Twb)
  • Возможность использовать прибор как портативного измерителя точки росы или как удаленного регистратора данных климатических условий (только модель Т)
  • Встроенный разъем типа К позволяет измерять температуру поверхности во время удаленной регистрации данных
  • Режим «Te» превращает прибор в простой термометр — идеально для измерения температуры покрытия перед нанесением или температуры внешних объектов
  • Функция удержания позволяет просмотреть отдельные показания перед записью в память.
  • Изготовлен из стойких к воздействию температур материалов, что позволяет использование при температурах от -20°C до +80°C
  • Защита корпуса от брызг и пыли по стандарту IP66
  • Прочная и эргономичная конструкция корпуса дополняется долговечными промышленными датчиками, выдерживающими тяжелые условия эксплуатации
  • Четкий дисплей с подсветкой работает во всём диапазоне рабочей температуры прибора.
  • Данные могут быть переданы в ПК через интерфейсы USB или Bluetooth и обработаны при помощи программного обеспечения ElcoMaster 2.0.
  • ПО ElcoMaster имеет уникальную функцию «Watchguard», позволяющую пользователю удаленно следить за показаниям до 42 приборов на одном экране (только моделей Т)
  • Любой прибор может питаться от 2 батарей типа AA (до 400 часов работы) или напрямую от порта USB.
  • Установка пределов измерения для каждого измеряемого параметра; при выходе параметра за пределы включается аудиовизуальная сигнализация, даже если он не отображается на дисплее.

Сравнение моделей Elcometer 319:

Модель Модель S Модель Т
Код заказа G319-S G319-T
Измеряемые параметры — RH, Ta, Ts, Td, TΔ, Tdb, Twb, SH1
Рассчитываемая статистика — количество измерений, стандартное отклонение, коэффициент вариации, минимальное, максимальное значение
Пыле и брызгозащищенный корпус с полностью герметичными датчиками — защита по стандарту IP66
Встроенные магниты для крепления прибора в режиме регистратора данных
Верхний/нижний пределы измерения — аудиовизуальная сигнализация, подсказки красным/зеленым LED индикатором могут быть установлены для любого или всех параметров
Многоязыковое меню
Подсветка дисплея — настраиваемая пользователем
Разъем типа K для подключения внешних датчиков
Память с просмотром результатов и статистики измерений Последние 10 показаний 25000 наборов данных в 999 группах
Режим ручной регистрации данных
Режим автоматической регистрации через интервалы времени с настройкой интервала2 Интервал от
1 секунды до
1 часа
Вывод данных: USB и беспроводное соединение Bluetooth
Программное обеспечение ElcoMaster & ElcoMaster Mobile
Диапазон температур Точность Разрешение
Температура воздуха (Ta): -20 — +80°C ±0,5°C 0,1°C
Температура поверхности (Ts): -20 — +80°C ±0,5°C 0,1°C
Внешняя термопара типа К (Te): -40 — +200ºC

±0,5ºC

0,1°C
Относительная влажность (RH): 0 — 100% RH ±3% RH 0,1%

Понравилась статья? Поделить с друзьями:

А вот и еще интересные новости по теме:

  • Тенотен детский инструкция по применению цена отзывы врачей родителей
  • Биография руководства страны
  • Кофасма сироп инструкция по применению взрослым дозировка
  • Инструкция по охране труда при пользовании бытовыми приборами
  • Joyetech exceed grip pro pod kit инструкция на русском

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии