-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
AR
NL
P
E
I
F
GB
D
INSTRUCTION MANUAL
Contactless Infrared
Thermometer
GT-101
17
Related Manuals for GERATHERM GT-101
Summary of Contents for GERATHERM GT-101
-
Page 1
INSTRUCTION MANUAL Contactless Infrared Thermometer GT-101… -
Page 2
Dear customer, Thank you for your confi dence in Geratherm ® and congratulations on your purchase! By purchasing the Geratherm non contact ther- ® mometer you have acquired a quality product by Geratherm ® This thermometer has been clinically tested and proven to be safe and accurate when used in ac- cordance with its operating instruction manual. -
Page 3: Table Of Contents
CONTENTS Descriptions of Parts Advantages of the Thermometer Safety Precautions Important Information about Temperature Measurement Technical Data Battery Replacement Alternating between Body and Object Mode Measuring Body Temperature Measuring the Temperature of an Object Alternating between Celsius and Fahrenheit Recalling Stored Data Error Messages Cleaning and Disinfection Disposal…
-
Page 4: Advantages Of The Thermometer
ADVANTAGES OF THE THERMOMETER Fast and contactless temperature measurement The innovative infrared technology ensures safe and hygienic temperature measurement within seconds. Multifunctions The extended measuring range (0 °C — 100 °C; 32 °F — 212 °F) permits the measurement of body temperature and of the temperature of ob- jects or surfaces, e.g.
-
Page 5: Safety Precautions
SAFETY PRECAUTIONS • This instrument may only be used for the pur- poses described in this booklet. • The thermometer is intended for private do- mestic use only. • The unit is not waterproof. Never immerse this instrument in any liquids. •…
-
Page 6: Technical Data
Temperature“ and draft standard IEC 80601-2-56 “Medical electrical equipment — Part 2-56: Par- ticular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement“. Geratherm is certi- ® fi ed in accordance with Council Directive 93/42/ EEC, Annex II and DIN EN ISO 13485 and is enti- tled to affi…
-
Page 7: Battery Replacement
BATTERY REPLACEMENT This instrument is supplied with 2 new, longlife 1.5 V size AAA batteries. The batteries need re- placing when this icon “ ” is the only symbol shown on the display. Slide the battery cover open and insert 2 new batteries, then close the battery cover again.
-
Page 8: Measuring Body Temperature
MEASURING BODY TEMPERATURE NOTES: • The thermometer and the patient must re- main in a room with a stable room tempera- ture for at least 30 minutes before measuring the temperature. • Do not take a baby’s temperature during or directly after breastfeeding.
-
Page 9
MEASURING BODY TEMPERATURE USE: 1. Press the ON/OFF button . The display is activated to show all segments for 2 seconds. 2. The last measurement reading will automati- cally be shown on the display for 2 seconds with the “M” icon. 3. -
Page 10: Measuring The Temperature Of An Object
• In the mouth (oral): 35.5 °C — 37.5 °C (95.9 °F — 99.5 °F) • In the armpit (axillary): 34.7°C — 37.3°C (94.5 °F — 99.1 °F) • Geratherm non contact: 35.4 °C — 37.4 °C ® (95.7 — 99.3 °F)
-
Page 11: Alternating Between Celsius
ALTERNATING BETWEEN °C AND °F To switch the display between °C and °F, sim- ply turn OFF the unit, then press and hold the START button for 5 seconds; after 5 seconds, the current measurement scale (“°C” or “°F” icon) will be fl ashing on the display. Now switch the measurement scale between °C and °F by pressing the START button.
-
Page 12: Error Messages
ERROR MESSAGES Display Description The measured temperature is too high H appears if the reading is above 42.2 °C (108 °F) in body mode or 100 °C (212 °F) in object mode. The measured temperature is too low L appears if the reading is below 34 °C (93.2 °F) in body mode or 0 °C (32 °F) in object mode.
-
Page 13: Cleaning And Disinfection
CLEANING AND DISINFECTION • Use a swab or cotton tissue moistened with alcohol (e.g. 70% Isopropyl) to clean the ther- mometer casing and the measuring probe. Ensure that no liquid enters the interior of the thermometer. Never use abrasive clean- ing agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids.
-
Page 14: Warranty
We recommend that the accuracy of the unit be checked annually by an authorised labora- tory (mandatory in Germany). This checking procedure is not a service provided under the warranty. Manufacturer: Geratherm Medical AG Fahrenheitstraße 1 D-98716 Geschwenda Germany…
-
Page 15
Model No.: …………Serial No.: …………Date of purchase: ……….Dealer’s signature: ………. Invoice No. / Receipt No.: ……. Name and address of dealer: ………………Manufacturer: Geratherm Medical AG Fahrenheitstraße 1 D-98716 Geschwenda Germany CONTACTLESS INFRARED THERMOMETER Geratherm ® non Contact…
Yes, the Geratherm® non Contact can be switched between Celsius and Fahrenheit.
To change the display from C to F, switch off the thermometer and press the START button for 5 seconds, after these 5 seconds the current measurement scale ( C or F symbol) lights up on the display.
Now switch the measurement scale between °C and °F by pressing the START button. Once you have selected the scale you want, wait 5 seconds for the thermometer to automatically switch to «Ready» mode for measurement.
Yes, the battery of the Geratherm® non Contact can be changed.
Caution: Keep the thermometer and batteries away from small children. If the battery is swallowed, contact a hospital immediately. Do not throw the battery into fire, it may explode.
No, the Geratherm® non Contact is a non-contact thermometer.
The thermometer measures the infrared energy emitted by the skin of the forehead. This energy is captured by lenses and converted into temperature readings. Temperature readings measured by scanning the area above the eyebrow are the most accurate.
Use a sponge soaked in alcohol or a cotton cloth dampened with alcohol (e.g. 70% isopropanol) to clean the thermometer housing and the measuring sensor. No liquid should get inside the thermometer. Don’t use aggressive ones Detergents, solvents or benzene for cleaning and never immerse the device in water or other cleaning liquids.
The Geratherm® non Contact is not waterproof.
The Geratherm® non Contact complies with IP 22 and is therefore protected against solid foreign objects with a diameter of 12.5 mm and more and against water dripping at an angle of up to 15 degrees.
Observe the correct application according to the instructions for use. Measure again while observing the maximum distance to the forehead of 2 cm.
If the value is low again, carry out a control measurement with a conventional clinical thermometer.
For newborns under 6 months, carry out a control measurement with a conventional clinical thermometer.
A control measurement should also be carried out in children under three years of age with a weak immune system, in which the presence or absence of fever is decisive.
Квесисская 2-я ул, 21, Москва
Сергиев Посад-6, 1А, Сергиево-Посадский р-н, МО (на въезде в Военный городок, на территории рынка)
г.Сергиев Посад, площадь Красногорская, д. 1
Никольская ул, 10, Москва
г.Жуковский, Чкалова, д. 41
Курыжова, 7, Южный мкр, Домодедово, МО
Энтузиастов ш, 3 к 1, Москва
Семеновская пл, 7 к 17А, Москва
Юшуньская малая. ул, 3, Москва
Нахимовский пр, 22, Москва
Шелепихинская наб, 34 к 2, Москва
Армавирская ул, 3, Москва
Пресненский Вал ул, 7c1, Москва
Авиаконструктора Миля ул, 4А, Москва
Новоугличское ш, 46, Сергиево-Посадский р-н, Сергиев Посад, МО
Вучетича ул, 22, Москва
Рижское ш, 41А, Волоколамск, МО
Ласточкин пр-д, 16, Балашиха, МО
Маршала Жукова пр, 49, Москва
Рязанский пр, 71к1, Москва